EasyManua.ls Logo

Fagor CNC8 070 - 1010: Program G4 K; 1011: G4: Dwell out of Range; 1012: G4: the Dwell Cannot be Programmed Using K; 1013: G4: the Dwell Cannot be Negative

Fagor CNC8 070
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CNC8070
R
EF
. 0402
OF 128
E
RROR
SOLUTIONS
Page 10 of 128
Errors 1000-1999
1010 'Program G4 K'
DETECTION During execution.
CAUSE The function has not been programmed correctly.
SOLUTION There are two ways to program the dwell with G4:
G4 <time>
•G4 K<time> .
In both cases, the dwell must be programmed after G4.
The second case does not allow "=" after "K".
1011 'G4: dwell out of range'
DETECTION During execution.
CAUSE Too large a value has been programmed for the dwell function G4.
SOLUTION The maximum value allowed for the dwell is 2147483646.
1012 'G4: the dwell cannot be programmed using K'
DETECTION During execution.
CAUSE The letter K is associated with the third axis of the channel and in this case there is
no third axis.
SOLUTION If a third axis is not desired in the channel, the dwell may be programmed directly with
a number.
1013 'G4: the dwell cannot be negative'
DETECTION During execution.
CAUSE A negative dwell has been programmed using function G4 or programming the #TIME
instruction.
SOLUTION The programmed dwell must be equal to or greater than zero.
1014 'It is no t possible to program in diameters with mirror image on the face axis'
DETECTION During execution.
CAUSE The face axis (machine parameter FACEAXIS = Yes) cannot have both the mirror
image and programming in diameters active at the same time.
SOLUTION Activate either the mirror image or diameter programming for the face axis.
1015 'Center coordinates out of range'
DETECTION During execution.
CAUSE Too large values of I, J, K have been programmed for the center of the circular
interpolation or for the center of rotation of the coordinate system.
SOLUTION Program smaller values.
1016 'Negative values cannot be used when programming an axis in diameters'
DETECTION During execution.
CAUSE When programming in absolute coordinates (function G90) a negative coordinate has
been programmed for an axis that is in diameters (machine parameter DIAMPROG).
SOLUTION Coordinates programmed in absolute coordinates for the axes in diameters must be
positive.
1017 'G198: negative software limit out of range'
DETECTION During execution.
CAUSE Too high a value has been programmed for the negative software limit.
SOLUTION Check the program.
1018 'G199: positive software limit out of range'
DETECTION During execution.
CAUSE Too high a value has been programmed for the positive software limit.
SOLUTION Check the program.