EasyManua.ls Logo

Fagor CNC8 070 - 1019: No Measurement Has Been Taken on the Requested Axis (Axes); 1020: Negative Ramp Time; 1021: Ramp Time out of Range; 1022: Percentage of Feed-Forward out of Range

Fagor CNC8 070
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 11 of 128
Errors 1000-1999
1019 'No measurement has been taken on the requested axis (axes)'
DETECTION During execution.
CAUSE Function G101is being used to include the measurement offset on an axis for which:
No previous measurement has been taken (G100).
The measurement taken (G100) has been canceled (G102).
SOLUTION Take a measurement with the axis on which to apply function G101.
1020 'Negative ramp time'
DETECTION During execution.
CAUSE Using function G132, a negative ramp time has been programmed.
SOLUTION The ramp time must be equal to or greater than zero.
1021 'Ramp time out of range'
DETECTION During execution.
CAUSE With function G132, a ramp time value too high has been programmed.
SOLUTION Check the program.
1022 'Percentage of Feed-Forward out of range'
DETECTION During execution.
CAUSE The probable causes are:
With function G134, too high a value has been programmed for the percentage
of Feed-Forward.
With function G135, too high a value has been programmed for the percentage
of AC-Forward.
SOLUTION The percentage of Feed-Forward or AC-Forward must be greater than zero and
smaller than 120.
1023 'Wrong set number
DETECTION During execution.
CAUSE The programmed set number for the axis is wrong.
SOLUTION The set programmed for the axis must be greater than zero and smaller than or equal
to machine parameter NPARSETS of the axis.
1024 'Set number out of range'
DETECTION During execution.
CAUSE The programmed parameter set value for the axis is too high.
SOLUTION The maximum value allowed for the set number is 65535.
1025 'Programmed distance equal to zero'
DETECTION During execution.
CAUSE No movement has been programmed in the G63 block.
SOLUTION Program a movement.
1026 'Wrong circular path with the programmed radius'
DETECTION During execution.
CAUSE The programmed radius for the circular interpolation is too small.
SOLUTION Check the program.
1027 'The starting point and the end point of the circular path are the same (infinite
solutions)'
DETECTION During execution.
CAUSE A zero radius has been programmed for the circular interpolation and there are infinite
solutions.
SOLUTION Check the program.

Table of Contents