Specifications of the DMS Go+ 11 Specifications
DMS Go+ Edition 4 (05/2014) 11-7
Protection
Damp heat and humidity (storage) 10 cycles: 10 hrs at +60+30 °C, 10 hrs at +30+60 °C,
transition within 2 hrs (507.4)
Temperature shock (storage) 3 cycles: 4 hrs at -20 +60 °C, 4 hrs at +60 °C
transition within 5 minutes (503.4, Procedure II)
Vibration: General exposure: 1 hr per axis,
514.5-5 Procedure I, Annex C, Figure 6
Shocks 6 cycles per axis, 15 g, 11 ms, half-sine (516.5 Procedure I)
Loose cargo
(in shipping containers)
514.5 Procedure II
Transit drop
(packaged for shipment)
26 drops, 516.5 Procedure IV
Enclosure IP67 according to IEC 529
Operating temperature range 0 … 55 °C