LANtools network management
BAT54-Rail/F..
Release
7.54
06/08
5.5
Rollout Wizard
203
D Checkmark: Simple option that can be switched on or off. Min.-Value
and Max.-Value are of no further significance for these entries. Check-
marks are activated as standard if the default value is not empty.
D Default: Label
D Min-Value
Minimum value for the current variable (if type = integer) or minimum num-
ber of characters (where type = String or Password).
D Possible values: 0 to 2
32
- 1
D Default: 0
D Max-Value
Maximum value for the current variable (if type = integer) or maximum
number of characters (where type = String or Password).
D Possible values: 0 to 2
32
- 1
D Default: 0
D Default value
Default value of the current variable.
D Possible values: Maximum 64 alphanumerical characters
D Default: blank
5.5.3 Actions to be executed by the Rollout Wizard
Max. 19 definitions of actions (with index and action) which are to be execut-
ed by the Rollout Wizard after the user data has been entered.
D Index
Index for the action. The Rollout Wizard executes the actions in ascend-
ing order.
D Possible values: 1 to 2
32
- 1
D Default: 0
D Action
Action to be executed by the Rollout Wizard after the user data has been
entered.
D Possible values: Similar to Cron commands, actions are entered in the
syntax
[Protocol:]Argument
. If no protocol is entered, 'exec.' is
applied.
D exec: Executes any command just as it is used in Telnet to configure
a BAT. The following example sets the name of the device to 'MyLAN-
COM':