12.7.3 Configuring the CRON job
The following parameters are available in the BAT for configuring CRON
jobs:
D Entry active
Activates or deactivates the entry.
D Default: Active
D Time base
The 'Time base' field determines whether time control is based on real
time or on the device's operating time.
D Real time: These rules evaluate all time/date information.
D Operation time: These rules only evaluate the minutes and hours since
the last time the device was started.
D Default: Real time
Configuration tool Call
LANconfig Date & time
 General  CRON table
WEBconfig, Telnet Expert configuration > Setup > Config > CRON table