Wireless LAN – WLAN
BAT54-Rail/F..
Release
7.54
06/08
3.7
IEEE 802.11i for point-to-point connections
107
3.7.3 Access points in relay mode
Access points equipped with two wireless modules can be used to establish
wireless bridges across multiple stations. Each wireless module is configured
as a 'Master' and then 'Slave' in turn.
Note: The use of relay stations each equipped with two WLAN modules si-
multaneously solves the problem of the "hidden station", by which the
MAC addresses of the WLAN clients are not transferred over multiple sta-
tions.
3.7.4 Security for point-to-point connections
IEEE 802.11i can be used to attain a significant increase in the security of
WLAN point-to-point connections. All of the advantages of 802.11i such as
the simple configuration and the powerful encryption with AES are thus avail-
able for P2P mode, as are the improved security of the passphrase from the
BAT Enhance Passphrase Security (LEPS).
U Encryption with 802.11i/WPA
To activate the 802.11i encryption for a correctly configured P2P connection,
adjust the settings for the first logical WLAN network in the appropriate
WLAN interface (i.e. WLAN-1 if you are using the first WLAN card for the P2P
connection, WLAN-2 if you are using the second card, e.g. as with an access
point with two WLAN modules).
D Activate the 802.11i encryption.
D Select the method '802.11i (WPA)-PSK'.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann BAT54-Rail and is the answer not in the manual?

Hirschmann BAT54-Rail Specifications

General IconGeneral
BrandHirschmann
ModelBAT54-Rail
CategoryWireless Access Point
LanguageEnglish

Related product manuals