Routing and WAN connections
442
11.13
 
Callback functions
BAT54-Rail/F..
Release
 
7.54
 
06/08
After the Authentication an input window appears on the caller's screen in 
Windows that requests the ISDN telephone number of the PC.
U The calling number is determined in the BAT
For this setting the callback entry must be set to 'Call back the remote site 
after name verification' (or must be set to the value 'Name' in WEBconfig or 
in the console). In the peer list one telephone number must be specified.
Some Windows versions (especially Windows 98) prompt the user to confirm 
the callback to the telephone number stored in the BAT ('Administrator Spec-
ified') with an input window. Other Windows versions only inform the user that 
the PC is waiting for the callback from the BAT.
The callback to a Windows workstation occurs approx. 15 seconds after the 
first connection has been dropped. This time setting cannot be decreased 
since it is a Windows default setting.
11.13.2Fast callback
This fast process is ideal if two BAT are to communicate with one another via 
callback.
D The caller who may wish to be called back can activate the function 'Wait 
for callback from remote site' in the peer list (or 'Looser' when configuring 
via WEBconfig, terminal program or Telnet).
D The callback party selects 'Call back the remote site (fast procedure)' in 
the peer list and enters the calling number ('fast' when configuring via 
WEBconfig, terminal program or Telnet).
Note: For fast callback using this method, the number list for answering calls 
must be kept up to date at both ends.