Routing and WAN connections
BAT54-Rail/F..
Release
7.54
06/08
11.7
Changes in other services
405
Initially the filters are defined in a central table; these can then used by en-
tries in the LAN and WAN RIP table.
WEBconfig: Setup
IP-router RIP Filter
D Name
Name of the filter.
D Possible values: 18 alphanumerical characters.
D Examples: LAN#1, LAN#2, WAN1, etc.
Note: The hash symbol # can be used to combine multiple entries into a sin-
gle filter. Taken together the entries LAN#1 and LAN#2 make up a filter
"LAN" that can be called from the RIP table.
D Filter
Comma-separated list of networks that are to be accepted (+) or rejected
(-).
D Example of an accepted network: +10.0.0.0/255.0.0.0
D Example of an unaccepted network: -192.168.0.0/255.255.0.0
D Possible values: 64 characters from
,+-/0123456789.
Note: The plus-sign for accepted networks is optional.
Filters defined in the filter table can be referenced in the columns for RX filter
and TX filter in the LAN RIP and WAN RIP tables. RX defines the networks
from which routes can be learned or blocked, and TX defines the networks to
which propagation should be allowed or blocked.
Caution: Filtering by routing tags is unaffected, i.e. if a tag for a route in-
dicates that it is not to be learned or propagated, then this cannot be
forced by means of the filter table.
U Global RIP parameters
U Maximum hop count
In some scenarios it may be desirable to use a larger maximum hop count
than that intended by RIP (16). This value can be adapted with the parameter
Max Hopcount.
D WEBconfig: Setup
IP-router RIP Parameters
D Max hop count
Sets the maximum number of permissible hops.
D Possible values: 16 to 99
D Default: 16