Routing and WAN connections
448
11.14
serial interface
BAT54-Rail/F..
Release
7.54
06/08
Note: The modem parameters are set with values that should suit most mo-
dems. Thus changes are generally not necessary. Refer to the documen-
tation for your modem for settings that vary from these.
Configuration with LANconfig
The modem parameters can be found in the LANconfig configuration area
'Interfaces' on the 'WAN' and 'Modem' tab.
U Setting up a GPRS backup connection
If the connection is to use a GPRS-capable modem at the serial interface,
you will need the APN name and the dial-up telephone number. The follow-
ing init-strings for the configuration apply to T-Mobile and Vodafone:
D T-Mobile
D Init-string:
L0X1M1S0=0+CGDCONT=1, “IP”, “internet.t-d1.de”
D Dial-up number:
*99#
D Vodafone
D Init-string:
L0X1M1S0=0+CGDCONT=1, “IP”, “web.vodafone.de”
D Dial-up number:
*99#
or
*99***1#