Release
7.54
06/08
12.8
PPPoE Servers
499
Configuration with WEBconfig, Telnet or SSH
Under WEBconfig, Telnet or SSH client you will find the settings for the PP-
PoE server under the following paths:
D Operating: The 'Operating' button switches the server on or off. The de-
fault value is 'Off'.
D Service: The name of the service offered is entered under 'Service'. This
enables a PPPoE client to select a certain PPPoE server that is entered
for the client.
D Session limit: The 'Session limit' specifies how often a client can be
logged on simultaneously with the same MAC address. Once the limit has
been reached, the server no longer responds to the client queries that are
received. Default value is '1', maximum value '99'. A Session limit of '0'
stands for an unlimited number of sessions.
Configuration tool Menu/Table
WEBconfig Expert configuration
 Setup  PPPoE server
Terminal/Telnet
Setup/PPPoE servers

Table of Contents