349
Use undo startup-query-interval to restore the default.
By default, the startup query interval is 1/4 of the "MLD query interval".
Related commands: mld startup-query-interval and timer query.
Examples
# Set the startup query interval to 5 seconds globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] startup-query-interval 5
timer other-querier-present (MLD view)
Syntax
timer other-querier-present interval
undo timer other-querier-present
View
MLD view
Default level
2: System level
Parameters
interval: Specifies an MLD other querier present interval in seconds, in the range of 60 to 300.
Description
Use timer other-querier-present to configure the MLD other querier present interval globally.
Use undo timer other-querier-present to restore the default.
By default, MLD other querier present interval = [ MLD query interval ] × [ MLD querier’s robustness
variable ] + [ maximum response delay for MLD general queries ] /2.
Related commands: display mld interface, max-response-time, mld timer other-querier-present,
robust-count, and timer query.
Examples
# Set the MLD other querier present interval to 200 seconds globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] timer other-querier-present 200
timer query (MLD view)
Syntax
timer query interval
undo timer query
View
MLD view

Table of Contents

Other manuals for HP 3600 v2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3600 v2 Series and is the answer not in the manual?

HP 3600 v2 Series Specifications

General IconGeneral
BrandHP
Model3600 v2 Series
CategorySwitch
LanguageEnglish

Related product manuals