4
DR MODE <ADVANCED>
4-18
Digital squelch functions (Continued) ■
D The digital code squelch setting
Hold down q for 1 second.
• The DR mode is selected.
•
To use the digital code squelch function in another mode,
push [V/MHz]
or [M/CALL] to select the VFO,
Memory or CALL channel mode.
Push w .
Push D-pad( e ) to select “DSQL,” and then push D-
pad(Ent).
Push D-pad( r ) to select “CSQL S” or “CSQL.”
• CSQL S : Turn ON the digital code squelch pocket
beep.
• CSQL : Turn ON the digital code squelch.
Push D-pad(Ent) to set the digital code squelch, and t
then exit the quick menu screen.
• “SQL” appears
.
• “CSQL S” or “CSQL” appears when
the VFO, Memory
or CALL channel mode is selected.
Push [MENU] y .
Push D-pad( u ) to select the root item (“DUP/
TONE...”), and then push D-pad(Ent).
Push D-pad( i ) to select “Digital Code,” and then
push D-pad(Ent).
Rotate [DIAL] to select a digital code between 00 o
and 99 for the digital code squelch function.
!0 Push [MENU] to set and exit the MENU
screen.
!1 When the received signal includes a matching code,
the squelch opens and the audio is heard.
• When the received signal’s code does not match, digital
code squelch does not open; however, the S/RF meter
shows the received signal strength.
NOTE:
While operating in the low-speed data com-
munication mode, the digital code squelch opens
even if receiving a signal does not match to your
digital code.
D Pocket beep function with the digital
code squelch
When a received signal matches your digital code, the
transceiver sounds beep tones for 30 seconds (except
for the DR mode, “S” blinks).
Push [PTT] to answer, or push D-pad(Ent) to stop ➥
the beeps or “S” blinking.
* Except for the DR mode, in which “S” disappears.
If no operation is performed for 30 seconds, the beep
tones automatically stop (except for the DR mode, in
which “S” continues to blink to inform you of a call).
Appears
When “CSQL S” or “CSQL” is selected in
the
VFO, Memory or CALL channel mode.