MENU GROUP OPTIONS
There are eight functional options which may be
set for a Menu Group.
Use the <RIGHT> Arrow, followed by the <9>
(Y) & <5> (N) keys to set the desired options to
YES or NO.
<OK> for next option. <UP> / <DOWN> to edit
this option for the previous/next Menu Group.
[R]emote Access. Allows remote access via Up/Download software.
[I]solate on Exit. Allows User to Isolate un-sealed zones on exit.
[D]efer Area On. Implements Area Defer timer operation when the
User turns an Area Off that has been defined as a
“Defer” Area. Area automatically re-arms when the
Defer timer expires, unless the User performs the
Area Off function again before the timer or warning
expires. (V2 or later only)
[C]ancel Holdup. Allows the User to cancel a Holdup alarm before it
reports, by entering their PIN at an LCD Terminal.
(V2 or later only)
[S]irens Off. Allows Users to automatically turn off any Sirens
running at the time of PIN code entry, regardless of
whether they are allowed control of the Area/s that
triggered the siren/s.
[A]cknowledge Messages. Allows Users to acknowledge alarm messages from
any Area, regardless of whether they are allowed
control of the Area/s that generated the message/s.
[M]ultiple Areas. Allows the User to turn On/Off more than one Area at
a time via an Area List. Any Area List can be chosen,
but only Areas in the User’s On/Off Lists will be
controlled.
[T]amper On/Off. Allows the User to turn Off the 24 Hr or Tamper part
of any Area in their Area OFF List.
or or