Testing: Menu Option 4
Testing simply involves activating the devices (usually detectors) and then allowing
them to return to their normal state. e.g. Walk past movement detectors, open and
close doors, press then release panic buttons, etc.
The system can perform automatic testing on devices that are regularly activated by
movement, etc., such as PIRs and Door Contacts. However, other types of Input
devices, such as Glass-break, Smoke & Seismic detectors, Panic buttons, Window
Contacts, etc. should also be tested on a regular basis. (e.g. Once every month)
NOTE: The additional Test Menu options shown in the Menu Flowchart at the rear of
this manual are only accessible to the Installer. They provide a comprehensive range
of Testing to assist with installation, commissioning and service of the system.
The display will prompt you to select an Area to
Test.
The <UP> and <DOWN> Arrows will search
through the Area names alphabetically,
OR
Press the <DIGIT> key that represents the first letter
of the name. (You may have to press the key 2 or 3
times to obtain the required letter.)
If the name you want is not displayed because of
other names starting with the same letter, use the
<DOWN> Arrow key to locate the name.
When the Area is selected, press the <OK> key to
proceed.
If the maximum time allowed for Walk Testing
expires, the test will be aborted and the display will
return to the “Area to Test?” prompt.
The maximum test time is programmed by the
Installer for each Area. If the max. test time for an
Area is set to zero, the maximum test time will then
be 10 minutes.






OR
then if required.
Your system may be programmed with an option
to allow Walk testing of specified Zones in
particular Areas. (V3 or later only)

Table of Contents

Other manuals for Inner Range Concept 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range Concept 4000 and is the answer not in the manual?

Inner Range Concept 4000 Specifications

General IconGeneral
BrandInner Range
ModelConcept 4000
CategoryTouch terminals
LanguageEnglish