97
CONCEPT 4000.CONCEPT 4000.
CONCEPT 4000.CONCEPT 4000.
CONCEPT 4000. User Manual.
UK RESET
The “UK Reset” option allows a User with the
appropriate authority to reset the “ON key
lockout” condition after an alarm.
IMPORTANT NOTE: This operation is only
relevant to specific countries (e.g. UK) and is only
available in V5.6 or later.
The “ON key lockout” condition is caused when a
“Confirmed” or “Fault” Alarm occurs in an Area.
This forces the User to contact either the Installer
or the Monitoring Station (ARC) before they are
able to arm an Area that has been locked out.
If an attempt is made to arm an Area that is locked
out, this screen is displayed to the User.
-ARC Reset. The User must logon to the LCD
Terminal, select this menu and make a note of the
Date and Time data appearing on the top line.
They must then contact the ARC with this
information and obtain a 4-digit Reset Code
(anticode).
Once a Reset Code (anticode) has been obtained,
simply enter the code using the <DIGIT> keys
followed by the <OK> key.
Only Areas that are currently Off and are included
in the User Type’s “Area Off List” will be reset.
If the Reset Code (anticode) is correct, the display
will show “Alarms reset” for several seconds to
confirm that the “ON key lockout” condition has
been reset, and then return to the Main Menu.
If the Reset Code (anticode) is incorrect, The display
will show “Reset Code Wrong!” briefly, then return
to the Main Menu.
























MISC.

Table of Contents

Other manuals for Inner Range Concept 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range Concept 4000 and is the answer not in the manual?

Inner Range Concept 4000 Specifications

General IconGeneral
BrandInner Range
ModelConcept 4000
CategoryTouch terminals
LanguageEnglish