5.11.18 System Setup – Settings – Config Network
The computer running SESWIN is connected to the INNOMAR “smart”, “compact”
and “xx-usv” topside units via Ethernet. For these models the “Config Network”
section is used to change the IP address of the topside unit if necessary.
For the other models this section is used to change the IP address of the internal
micro-controller for UDP motion data, if required (see section 5.11.14 on page 70).
The actual IP address used by the topside
unit is displayed for reference.
You can check if the new address is already
in use by the “Ping” button. (On Windows
7/8/10 this “ping” needs to run the SESWIN
application with administrator privileges!)
In case the system gets an answer on the
network ping, a message is shown that the
chosen address is already used (see below).
Before the address is changed on the topside unit, there is a warning message displayed. Please
note the new address on the topside unit, you need to know it for future connections to
the kit.