108 Keysight N9010A EXA Service Guide
Instrument Messages
-200 to -299, Execution Errors
-231 Data questionable Indicates that the measurement accuracy is suspect
-232 Invalid format A data element was found but it could not be used because the data
format or the data structure was not correct.
-232 Invalid format; Map
information not loaded
Instrument failed to load the burst mapping information from the
selected file.
-233 Invalid version A legal data element was found but could not be used because the
version of the data is incorrect. For example, state data changes as
new instrument features are added, so old state files may not work in
an instrument with a newer version of software.
-240 Hardware error A legal program command or query could not be executed because of
a hardware error. The exact problem cannot be specifically identified.
-240 Hardware error; See details
in Windows Event Log under
SA
The internal data acquisition system detected a problem at startup
and logged the details in the Windows Event Log.
-241 Hardware missing The operation could not be performed because of missing hardware;
perhaps the optional hardware is not installed.
-241 Hardware missing; Internal
preamp not available at all
frequency points
The Internal Preamp is currently turned on, but the measurement is
being performed completely or partially outside the range of the
preamp. It is recommended that the user turns preamp off to ensure
consistent results across the entire measurement.
-241 Hardware missing; not
available for this model
number
The hardware required is not part of this model
-241 Hardware missing; Option
not installed
The optional hardware is not installed.
-250 Mass storage error; A problem was found with the mass storage device (memory, disk
drive, etc.). The exact problem cannot be specifically identified.
-250 Mass storage error; Access
denied
Access is denied.
-250 Mass storage error; Bad
path name
The specified path is invalid.
-250 Mass storage error; Can
only import single trace
.csv files
Trace files containing multiple traces can not be imported. However, if
you need to recall multiple traces you can use the Save and Recall
functions rather than the Import and Export functions.
-250 Mass storage error; Cannot
make
The directory or file cannot be created.
-250 Mass storage error;
Different Antenna Unit
already in use
Attempt to import Corrections file with Antenna Unit that differs from
an in-use correction.
-250 Mass storage error;
Directory not found
The system cannot find the path specified.