EasyManuals Logo

Keysight EXA N9010A User Manual

Keysight EXA N9010A
1138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
3 Programming the Analyzer
List of SCPI Commands
CALCulate:APD:LLINe[1]:TRACe?
CALCulate:APD:MARKer:AOFF
CALCulate:APD:MARKer:COUPle[:STATe] OFF | ON | 0 | 1
CALCulate:APD:MARKer:COUPle[:STATe]?
CALCulate:APD:MARKer[1]|2|...|12:MAXimum
CALCulate:APD:MARKer[1]|2|...|12:MODE POSition | DELTa | OFF
CALCulate:APD:MARKer[1]|2|...|12:MODE?
CALCulate:APD:MARKer[1]|2|...|12:REFerence <integer>
CALCulate:APD:MARKer[1]|2|...|12:REFerence?
CALCulate:APD:MARKer[1]|2|...|12[:SET]:SLISt
CALCulate:APD:MARKer[1]|2|...|12:TRACe MEAS | MEAS2 | ELIMit
CALCulate:APD:MARKer[1]|2|...|12:TRACe?
CALCulate:APD:MARKer[1]|2|...|12:X <rel_ampl>
CALCulate:APD:MARKer[1]|2|...|12:X?
CALCulate:APD:MARKer[1]|2|...|12:Y?
CALCulate:APD:SLISt:APPend
CALCulate:APD:SLISt:REPLace <integer>
CALCulate:APD:TRACe[1]|2:FAIL?
CALCulate:CLIMits:FAIL?
CALCulate:DANalyzer:DLISt:COMMent <integer>, string
CALCulate:DANalyzer:DLISt:COMMent? <integer>
CALCulate:DANalyzer:DLISt:DELete:ALL
CALCulate:DANalyzer:DLISt:SORT:AUTO ON | OFF | 1 | 0
CALCulate:DANalyzer:DLISt:SORT:AUTO?
CALCulate:DANalyzer:DLISt:SORT:DAMPlitude ?
CALCulate:DANalyzer:DLISt:SORT:DAMPlitude PEAK | QPEak
CALCulate:DANalyzer:DLISt:SORT:ORDer ASCending | DESCending
CALCulate:DANalyzer:DLISt:SORT:ORDer?
CALCulate:DANalyzer:DLISt:SORT:TYPE DURation | DAMPlitude | TDISturbance |
TIME
CALCulate:DANalyzer:DLISt:SORT:TYPE?
CALCulate:DANalyzer:DLISt:ZOOM <integer>
CALCulate:DANalyzer:DLISt:ZOOM:OUT
CALCulate:DANalyzer:LIMit <amptd>
CALCulate:DANalyzer:LIMit?
CALCulate:DANalyzer:LIMit:AUTO ON | OFF | 1 | 0
CALCulate:DANalyzer:LIMit:AUTO?
CALCulate:DANalyzer:LIMit:CISPr:TERMinal MAINS | LOAD | MP1 | MP2 | MP3
CALCulate:DANalyzer:LIMit:CISPr:TERMinal?
CALCulate:DANalyzer:MARKer:AOFF
CALCulate:DANalyzer:MARKer:COUPle[:STATe] ON | OFF | 1 | 0
CALCulate:DANalyzer:MARKer:COUPle[:STATe]?
CALCulate:DANalyzer:MARKer[1]|2|...|12:FUNCtion:PREVious:ZOOM
CALCulate:DANalyzer:MARKer[1]|2|...|12:FUNCtion:ZOOM
CALCulate:DANalyzer:MARKer[1]|2|...|12:FUNCtion:ZOOM:CLEar
CALCulate:DANalyzer:MARKer[1]|2|...|12:FUNCtion:ZOOM:OUT
CALCulate:DANalyzer:MARKer[1]|2|...|12:MAXimum
CALCulate:DANalyzer:MARKer[1]|2|...|12:MAXimum:NEXT
CALCulate:DANalyzer:MARKer[1]|2|...|12:MINimum
CALCulate:DANalyzer:MARKer[1]|2|...|12:MODE POSition | DELTa | OFF
CALCulate:DANalyzer:MARKer[1]|2|...|12:MODE?
CALCulate:DANalyzer:MARKer[1]|2|...|12:REFerence <integer>
CALCulate:DANalyzer:MARKer[1]|2|...|12:REFerence?
70 EMI Receiver Mode Reference

Table of Contents

Other manuals for Keysight EXA N9010A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight EXA N9010A and is the answer not in the manual?

Keysight EXA N9010A Specifications

General IconGeneral
BrandKeysight
ModelEXA N9010A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals