3 Programming the Analyzer
List of SCPI Commands
CALCulate:DANalyzer:MARKer[1]|2|...|12[:SET]:DELTa:SPAN
CALCulate:DANalyzer:MARKer[1]|2|...|12:TRACe 1 | 2
CALCulate:DANalyzer:MARKer[1]|2|...|12:TRACe?
CALCulate:DANalyzer:MARKer[1]|2|...|12:X <real>
CALCulate:DANalyzer:MARKer[1]|2|...|12:X?
CALCulate:DANalyzer:MARKer[1]|2|...|12:Y?
CALCulate:DANalyzer:TABLe:DISPlay OFF | ON | 0 | 1
CALCulate:DANalyzer:TABLe:DISPlay?
CALCulate:DATA<n>:COMPress? BLOCk | CFIT | MAXimum | MINimum | MEAN |
DMEan | RMS | RMSCubed | SAMPle | SDEViation | PPHase[, <soffset>[,
<length>[, <roffset>[, <rlimit>]]]]
CALCulate:DATA[n]?
CALCulate:DATA[1]|2|...|6:PEAKs? <threshold>, <excursion>[, AMPLitude |
FREQuency | TIME]
CALCulate:DATA[1]|2|...|6:PEAKs? <threshold>, <excursion>[, AMPLitude |
FREQuency | TIME[, ALL | GTDLine | LTDLine]]
CALCulate[1]|2:DELTamarker[1]|2|...|4:MAXimum:LEFT
CALCulate[1]|2:DELTamarker[1]|2|...|4:MAXimum:NEXT
CALCulate[1]|2:DELTamarker[1]|2|...|4:MAXimum[:PEAK]
CALCulate[1]|2:DELTamarker[1]|2|...|4:MAXimum:RIGHt
CALCulate[1]|2:DELTamarker[1]|2|...|4:MINimum[:PEAK]
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe] ON | OFF | 1 | 0
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe] ON | OFF | 1 | 0
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe] ON | OFF | 1 | 0
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe]?
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe]?
CALCulate[1]|2:DELTamarker[1]|2|...|4[:STATe]?
CALCulate[1]|2:DELTamarker[1]|2|...|4:X <value>
CALCulate[1]|2:DELTamarker[1]|2|...|4:X <value>
CALCulate[1]|2:DELTamarker[1]|2|...|4:X <value>
CALCulate[1]|2:DELTamarker[1]|2|...|4:X?
CALCulate[1]|2:DELTamarker[1]|2|...|4:X?
CALCulate[1]|2:DELTamarker[1]|2|...|4:X?
CALCulate[1]|2:DELTamarker[1]|2|...|4:Y?
CALCulate[1]|2:DELTamarker[1]|2|...|4:Y?
CALCulate[1]|2:DELTamarker[1]|2|...|4:Y?
CALCulate:EMI:SLISt:CLEar ALL | CURRent
CALCulate:EMI:SLISt:DELete ALL | CURRent | MARKed | UNMarked
CALCulate:EMI:SLISt:MARK CURRent | DUPLicate | ALL
CALCulate:FSCan:LLINe:ALL:DELete
CALCulate:FSCan:LLINe[1]|2|...|6:AMPLitude:CMODe:RELative ON | OFF | 1 | 0
CALCulate:FSCan:LLINe[1]|2|...|6:AMPLitude:CMODe:RELative?
CALCulate:FSCan:LLINe[1]|2|...|6:AMPLitude:INTerpolate:TYPE LOGarithmic |
LINear
CALCulate:FSCan:LLINe[1]|2|...|6:AMPLitude:INTerpolate:TYPE?
CALCulate:FSCan:LLINe[1]|2|...|6:BUILd TRACE1 | TRACE2 | TRACE3
CALCulate:FSCan:LLINe[1]|2|...|6:COMMent ?
CALCulate:FSCan:LLINe[1]|2|...|6:COMMent "string"
CALCulate:FSCan:LLINe[1]|2|...|6:CONTrol[:DATA] <x>, <x>, ...
CALCulate:FSCan:LLINe[1]|2|...|6:CONTrol[:DATA]?
CALCulate:FSCan:LLINe[1]|2|...|6:CONTrol:INTerpolate:TYPE LOGarithmic |
LINear
EMI Receiver Mode Reference 71

Table of Contents

Other manuals for Keysight EXA N9010A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight EXA N9010A and is the answer not in the manual?

Keysight EXA N9010A Specifications

General IconGeneral
BrandKeysight
ModelEXA N9010A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals