9.1 Error code list
When an error occurs in the CSD-709, the code showing the type of error appears in the load window.
The table below shows error codes, meanings, the behavior of the CSD-709 in response to errors,
and remedial actions.
Error code Meaning
Behavior of CSD-709
Remedial action
Zero set is executed
outside the effective
range.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
Invalid function is
selected.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
Incorrect setting is
made in calibration.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
AD conversion is
terminated.
The error code
appears, and the
measurement is
terminated.
Turn off power once and restart the
equipment.
Incorrect operation is
executed during
confirmation with
CHECK value.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
Zero fine adjustment or span
fine adjustment is executed
although zero set, or peak is
turned on.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
Value set to function is
out of range.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
An attempt is made to
change the settings of
CF-30 to CF-41 although the
model is not identified by
[-07] or [-29]
.
The error code
flashes.
After the error code flashes for two
seconds, it is reset automatically.
Write error occurs on
EEPROM.
The error code
appears, and the
measurement is
terminated.
Turn off power once and restart the
equipment.
Option recognition error
occurs.
The error code
appears, and the
measurement is
terminated.
Turn off power once and restart the
equipment.
Read error occurs on
EEPROM.
The error code
appears, and the
measurement is
terminated.
Turn off power once and restart the
equipment.
Power-on sequence is
executed with the hold
signal turned on.
The error code
flashes.
Turn off the hold signal.
Displayed value
exceeds the upper limit
of the allowable range.
The error code is
displayed.
Enter a value that stays within the
allowable range.

Table of Contents

Other manuals for Minebea CSD-709

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea CSD-709 and is the answer not in the manual?

Minebea CSD-709 Specifications

General IconGeneral
BrandMinebea
ModelCSD-709
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals