10.4Troubleshooting
ProcedureSteps
1RemovetheDCpowercablefromthecradle.
2Dipthecottonportionofthecotton-tippedapplicatorinisopropylalcohol.
3Rubthecottonportionofthecotton-tippedapplicatoralongthepinsoftheconnector.Slowlymovethe
applicatorback-and-forthfromonesideoftheconnectortotheother.Donotleaveanycottonresidueonthe
connector.
4Allsidesoftheconnectorshouldalsoberubbedwiththecotton-tippedapplicator.
Donotpointnozzleatyourselfandothers,ensurethenozzleortubeispointedawayfromyourface.
5Spraycompressedairintheconnectorareabypointingthetube/nozzleabout½inchawayfromthesurface.
6Removeanylintleftbythecotton-tippedapplicator.
7Ifgreaseandotherdirtcanbefoundonotherareasofthecradle,usealint-freeclothandalcoholtoremove.
8Allowatleast10to30minutes(dependingonambienttemperatureandhumidity)forthealcoholtoairdry
beforeapplyingpowertocradle.
Ifthetemperatureislowandhumidityishigh,longerdryingtimeisrequired.Warmtemperatureanddry
humidityrequireslessdryingtime.
10.4Troubleshooting
Thefollowingtablesprovidestypicalproblemsthatmightariseandthesolutionforcorrectingtheproblem.
MN000112A01-September2013