Program 15 : Extension, Basic Setup
15-24 : Registration of Standard SIP Terminal
Level:
IN
(This Program is available for V1.5 or higher)
Description
Use Program 15-24 : Registration of Standard SIP Terminal to register data in the standard SIP
terminal where Register is not used.
Input Data
Item
No.
Item Input Data Description Default
01 Using IP Address 0.0.0.0 ~
255.255.255.255
IP Address of the standard SIP terminal
that is used as the SIP extension. When
Program 15-24-03 is set to 1, this Program
cannot be changed from 0.0.0.0 (except
using PCProgramming).
0.0.0.0
02 Call Procedure Port 0 ~ 65535 Call procedure port of the standard SIP
terminal that is used as SIP extension.
5060
03 Registration Setting
when REGISTER isn't
used
0 = Disable
1 = Enable
Enables or disables the Registration meth-
od. An error will occur if Program 15-24-01
is 0.0.0.0 and this Program is set to 1 (ex-
cept using PCProgramming).
0
Conditions
None
Feature Cross Reference
None
ISSUE 6.0 SL1100
Programming Manual 2-161
Program
15