Program 90 : Maintenance Program
90-11 : Alarm Report SMTP Setting
Level:
IN
Description
Use Program 90-11 : Alarm Report SMTP Setting to define the details of the system alarm report.
Input Data
Item
No.
Item Input Data Description Default Related
Program
02 Report Method 0 = No Report
1 = E-mail Address
When alarm reports are e-mailed,
set this option to 1. E-mail address
set in 90-11-08.
0
06 SMTP Host Name Up to 255 Characters When alarm reports are e-mailed,
set the SMTP name (ex : smtp.your-
isp.com). Contact your ISP (internet
service provider) for the correct en-
try if needed.
No Setting
07 SMTP Host Port
Number
0 ~ 65535 When alarm reports are e-mailed,
set the SMTP host port number.
Contact your ISP (internet service
provider) for the correct entry if nee-
ded.
25
08 To E-mail Ad-
dress
Up to 255 Characters When alarm reports are e-mailed,
set this e-mail address to which the
report should be sent.
No Setting
09 Reply Address Up to 255 Characters When alarm reports are e-mailed,
set the e-mail address where replies
should be e-mailed.
No Setting
10 From Address Up to 255 Characters When alarm reports are e-mailed,
set this e-mail address for the sta-
tion sending the report.
No Setting
11 DNS Primary Ad-
dress
0.0.0.0 ~
255.255.255.255
When alarm reports are e-mailed,
set the DNS primary address.
0.0.0.0
12 DNS Secondary
Address
0.0.0.0 ~
255.255.255.255
When alarm reports are e-mailed,
set the DNS secondary address.
0.0.0.0
13 Customer Name Up to 255 Characters When alarm reports are e-mailed,
enter a name to identify the particu-
lar system.
No Setting
14 Use Standard
SMTP Settings
(V2.0 Added)
0 = No
1 = Yes
In case of YES uses a PRG47-18
SMTP client.( MEMDB/CF mounting
is required.)
To Address (PRG 90-11-08), CC
Mail Address (PRG 90-25-01) Up to
48 characters.
In case of No uses a PRG 90-11
SMTP client.
0 90-11-08
90-25-01
47-18
90-11
ISSUE 6.0 SL1100