Program 20 : System Option Setup
20-01 : System Options
Level:
IN
Description
Use Program 20-01 : System Options to set various system options.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Operator Access
Mode
0 = Step Call
1 = Circular
Use this program to set up priority of
a call when calling an operator tele-
phone.
0 20-17
02 Text Message
Mode
0 = Call mode
1 = No Answer/Busy
mode
Use this program to select the mode
when calling the telephone which
set up the text message.
1 11-11-14
15-07-08
04 Interval timer for
BLF Data (V1.5
Added)
0 ~ 64800
(0 ~ 6480 seconds)
While on Networking Operation It
sends a BLF message to other sys-
tem interval of per 100s.
0
05 DTMF Receive
Active Time
0 ~ 64800 seconds For OPXs, analog telephones and
certain analog trunks (like DISA),
the system attaches a DTMF receiv-
er to the port for this time. The sys-
tem releases the receiver after the
time expires.
10 25-07-01
06 Alarm Duration 0 ~ 64800 seconds This time sets the duration of the
alarm signal.
30 11-11-12
07 Callback Ring
Duration Time
0 ~ 64800 seconds Callback rings an extension for this
time.
15 11-12-05
15-07-35
08 Trunk Queuing
Callback Time
0 ~ 64800 seconds Trunk Queuing callback rings an ex-
tension for this time.
15 11-12-05
15-07-35
09 Callback/Trunk
Queuing Cancel
Time
0 ~ 64800 seconds The system cancels an extension
Callback or Trunk Queuing request
after this time.
64800 11-12-05
15-07-35
10 Trunk Guard
Timer
0 ~ 64800 seconds The amount of time the system
waits to seize the next outside line
after the system releases an outside
line.
1
12 Telephone/Web
Pro Logout Time
1 ~ 86400
(86400 seconds = 1
day)
The system automatically logs out of
a Telephone/Web Pro session after
inactivity lasting this time.
900
(15 min.)
16 Mobile Extension
Callback time
1 ~ 64800 seconds The amount of time the system
waits to until system ends the call
back.
15 15-22-04
17 Day/Night
Change Key
Mode
0 = Toggle (Will follow
PRG 12-08-01.)
1 = Skip (When press-
ed the system will step
to the next night mode
time period in PRG
12-02.)
This program sets the operation
mode for the Night Mode Key (PRG
15-07 key 09).
0 (V4.0
Changed)
15-07
SL1100 ISSUE 6.0
2-168 Program 20 : System Option Setup
Program
20