EasyManua.ls Logo

NEC SL1100 - Program 80: Basic Hardware Setup for System; Service Tone Setup; Table 2-13 Basic Tones

NEC SL1100
650 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Level:
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is
defined by the combination of 32 Basic Tones.
Input Data
Service Tone Number 01 ~ 64
Item
No.
Item Input Data Default
01 Repeat Count 0 ~ 255 (0 = Endless) Refer below
Unit Number 1 ~ 8
Item
No.
Item Input Data Default
02 Basic Tone Number 0 ~ 33
(0 = No Tone)
(33 = Default Time Slot)
Refer below
03 Duration Count 0 ~ 255 (0, 100 ~ 25500 ms) Refer below
04 Gain Level (dB) 0 ~ 63 (- 15.5 ~ + 15.5) Refer below
Table 2-13 Basic Tones
Basic Tone No. Frequency (Hz) Level (dB)
01 400 - 13
02 520 - 13
03 580 - 13
04 660 - 13
05 700 - 13
06 800 - 13
07 880 - 13
08 1050 - 13
09 350 / 440 - 16 / - 16
10 440 / 480 - 16 / - 16
11 480 / 620 - 21 / - 21
12 440 -16
13 -- Reserve -- -
14 520 / 650 -19 / -13
ISSUE 6.0 SL1100
Programming Manual 2-449
Program
80

Table of Contents

Other manuals for NEC SL1100

Related product manuals