Program 34 : Tie Line Setup
34-04 : E&M Tie Line Toll Restriction Class
Level:
IN
Description
Use Program 34-04 : E&M Tie Line Toll Restriction Class to enter a Toll Restriction Class for each
Tie Line. There are 15 Toll Restriction Classes which are defined in Programs 21-05 and 21-06. For
each Tie Line, you make a separate Toll Restriction Class entry for each Night Service mode.
Input Data
Trunk Port Number 001 ~ 084
Day/Night Mode 1 ~ 8
Item
No.
Item Input Data Default Related
Program
01 Toll Restriction Class 1 ~ 15 2 21-05
14-01-08
Conditions
• Program 20-06 cannot be used to assign Toll Restriction to Tie Lines.
Feature Cross Reference
None
SL1100 ISSUE 6.0
2-340 Program 34 : Tie Line Setup
Program
34