Program 82 : Basic Hardware Setup for
Extension
82-21 : Sensor Setup
Level:
IN
Description
Use Program 82-21 : Sensor Setup to setup the Sensor for SL1100.
Input Data
Sensor Number 1 ~ 6
Item
No.
Item Input Data Description Default
01 Sensor Type 0 = Close Detect
1 = Open Detect
Set sensor type. 0
02 Sensor Alarm Detect
Minimum Level
1 ~ 255 (5 ms ~ 1275
ms)
Set minimum level for Alarm detection. 24 (120 ms)
03 Sensor Idle Detect
Minimum Level
1 ~ 255 (5 ms ~ 1275
ms)
Set minimum level for Idle detection. 24 (120 ms)
Conditions
None