Program 10 : System Configuration Setup
10-03 : ETU Setup
Level:
IN
Description
Use Program 10-03 : ETU Setup to setup and confirm the Basic Configuration data for each unit.
When changing a defined terminal type, first set the type to 0 and then plug the new device in to have
the system automatically define it or you may have to reseat the unit.
The items highlighted in gray are read only and cannot be changed.
Input Data
Slot No. 00 ~ 15 (V3.5 Changed)
For ESIU PKG Setup
Physical Port Number
01 ~ 08
Item
No.
Item Input Data Description Default
01 Terminal Type (B1) 0 = No setting
1 = Multi-Line Telephone
10 = DSS Console
0
02 Logical Port Number 0 = No setting
1 = Multi-Line Telephone (1 ~
96 (V3.5 Changed) )
10 = DSS Console (1 ~ 12)
0
10 Bottom option information 0 = None
4 = WHA
0
12 Multi-Line Telephone Line 0 = None
12 = 12 Line
Terminal Type (B1)
24 = 24 Line
This program can on-
ly be change by using
PC Programming.
0
For SLIU PKG Setup
Physical Port Number
01 ~ 08
Item No. Item Input Data Default
01 Logical Port Number 0 ~ 112 (V3.5 Changed) 0
03 Transmit Gain Level (S-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
04 Receive Gain Level (R-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
05 Select port type 0 = SLT
1 = Door Phone
0
ISSUE 6.0 SL1100
Programming Manual 2-5
Program
10