EasyManua.ls Logo

NEC SL1100 - Toll Restriction for Trunks (Seized Trunk Basis Setting)

NEC SL1100
650 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 21 : Outgoing Call Setup
21-21 : Toll Restriction for Trunks (Seized Trunk Basis
Setting)
Level:
IN
Description
Use Program 21-21 : Toll Restriction for Trunks (Seized Trunk Basis Setting) to define the toll
restriction class to each trunk. The details of toll restriction are defined by Programs 21-05 and 21-06.
This program is compared to Station Restriction Class. The higher class is applied.
Input Data
Trunk Port Number 001 ~ 084
Day/Night Mode 1 ~ 9 (9 = Power Failure mode)
Item
No.
Item Input Data Description Default Related
Program
01 Restriction Class 1 ~ 15 = Toll Class 1 ~
15
Per Day/Night Mode assign a toll re-
striction class to each trunk.
It is recommended to not use class
2, because by default all stations
are assigned in class 2.
1 14-01-08
21-05
Conditions
None
Feature Cross Reference
None
SL1100 ISSUE 6.0
2-250 Program 21 : Outgoing Call Setup
Program
21

Table of Contents

Other manuals for NEC SL1100