Program 24 : Hold/Transfer Setup
24-02 : System Options for Transfer
Level:
IN
Description
Use Program 24-02 : System Options for Transfer to define the system options for the Transfer
feature.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Busy Transfer 0 = Disable (No)
1 = Enable (Yes)
Use this option to prevent or allow
extensions to Transfer calls to busy
extensions. If disabled, calls trans-
ferred to busy extensions recall im-
mediately.
1
02 MOH or Ring-
back on Trans-
ferred Calls
0 = Hold Tone
1 = Ring Back Tone
Use this option to enable or disable
MOH on Transfer. If enabled (0), a
transferred caller hears MOH while
their call rings the destination exten-
sion. If disabled (1), a transferred
caller hears ringback while their call
rings the destination extension.
1 (V1.5
Changed)
20-03-02
03 Delayed Call For-
warding Time
0 ~ 64800 seconds If activated at an extension, Delayed
Call Forwarding occurs after this
time. This also sets how long a
Transferred call waits at an exten-
sion forwarded to Voice Mail before
routing to the called extension mail-
box.
10 20-31-15
04 Transfer Recall
Time
0 ~ 64800 seconds An unanswered transferred call re-
calls to the extension that initially
transferred it after this time.
20 (V1.5
Changed)
20-31-16
05 Message Wait
Ring Interval
Time
0 ~ 64800 seconds For Single Line Telephones (SLTs)
without message waiting lamps, this
is the time between intermittent ring-
ing. If this value is set to 0, the sys-
tem rings once.
30
07 Trunk-to-Trunk
Transfer Release
Warning Tone
0 ~ 64800 seconds Time starts when a trunk begins
talking with another trunk (for exam-
ple : trunk-to-trunk transfer, outgoing
from trunk, Tandem Trunking).
When this time expires, a warning
tone is heard. If Program 24-02-10
is set, the conversation disconnects
after time expires. This time is set
again when the external digit timer
expires. One of the trunks used
must be an analog trunk (or leased
line).
1800 14-01-25
20-28-01
20-28-02
20-28-03
24-02-10
08 Delayed Transfer
Time for all De-
partment Groups
0 ~ 64800 seconds 10 11-11-28
11-11-29
15-07-59
ISSUE 6.0 SL1100
Programming Manual 2-283
Program
24