Program 82 : Basic Hardware Setup for
Extension
82-12 : OPX Initial Data Setup
Level:
IN
Description
Use Program 82-12 : OPX Initial Data Setup to define the various initial data for OPX packages.
Input Data
Item
No.
Item Input Data Description Default
01 Bounce Protect Time 0 = No setting
1 ~ 15 = 100 ms ~ 1.5
sec
Specify a time for detection of a valid off-
Hook indication that is long enough to pre-
vent an unintentional bounce of the receiv-
er from being detected as a new Off-Hook
indication from a single line telephone.
3
(300 ms)
02 HookFlash Start Time 0 = 40 ms
1 ~ 15 = 90 ms ~ 790 ms
Specify the minimum hookflash time from
a single line telephone or analog Voice
Mail system before it is detected as the be-
ginning of a valid hookflash.
5
(290 ms)
03 HookFlash End Time 0 = HST + 0 ms
1 ~ 15 = HST + 100 ms
~ HST + 1500 ms
(HST = Hookflash Start
Time)
Specify the maximum hookflash duration
from a single line telephone to receive a
second dial tone.
7
(990 ms)
Conditions
None
Feature Cross Reference
None
SL1100
ISSUE 6.0
2-490 Program 82 : Basic Hardware Setup for Extension