Program 10 : System Configuration Setup
10-36 : SIP Trunk Registration Information Setup
Level:
IN
Description
Use Program 10-36 : SIP Trunk Registration Information Setup to set the SIP trunk registration
information.
Input Data
Profile
(V5.0 Added)
1 ~ 2
Register ID 0 ~ 31 (V5.0 Changed)
Item
No.
Item Input Data Description Default
01 Registration 0 = Disable
1 = Enable
This setting determines if the SIP trunk in-
formation is registered.
0
02 User ID Up to 32 Characters
When assigning the
User ID, the ID may con-
tain only alpha charac-
ters. (A space and/or
special characters are
not allowed in the User
ID field). (V5.0 Added)
(ex. : UserID@Host-
Name.DomainName)
(V5.0 Added)
User ID in the SIP Invite Setup message.
Use it for outbound caller ID information if
no information is assigned in commands
21-17, 21-19, 15-16, 14-12 and 10-36. A
call cannot be completed across the span
if there is no outbound CID info. The rea-
son for this is: the from and display portion
of the invite message would be blank, and
it would not know where the call originated
from. (V5.0 Changed)
No Setting
03 Authentication User
ID
Up to 64 Characters This sets the user name of the SIP trunk.
(V5.0 Changed)
No Setting
04 Authentication Pass-
word
Up to 32 Characters This sets the SIP trunk password. (V5.0
Changed)
No Setting
Conditions