Program 21 : Outgoing Call Setup
21-10 : Dial Block Restriction Class Per Extension
Level:
IN
Description
Use Program 21-10 : Dial Block Restriction Class Per Extension to define the Toll Restriction
Class to each extension when the extension is set for Dial Block Restriction. If this data is 0, Toll
Restriction Class follows Program 21-09-01.
Input Data
Extension Number Maximum eight digits
Item
No.
Item Input Data Default
01 Toll Restriction Class 0, 1 ~ 15
(0 = No Setting)
0
Conditions
None
Feature Cross Reference
None
SL1100 ISSUE 6.0
2-240 Program 21 : Outgoing Call Setup