Program 20 : System Option Setup
20-17 : Operator Extension
Level:
IN
Description
Use Program 20-17 : Operator Extension to designate an operator. When an extension user dials 0
(defined by Program 11-01 Type 5), calls go to the operator selected in this program.
If you do not assign an extension in Program 90-11-01, system alarms appear on the extension
assigned in this option.
Input Data
Operator Number 1 ~ 8
Item
No.
Item Input Data Description Default Related
Program
01 Operators Ex-
tension Number
Up to eight digits Define the extension numbers which
are to be used by operators.
101 11-01
20-01-01
02 Operator Con-
sole
0 = Normal Key Set
1 = Special Operator
Console
Determines an operator console
type when any extension user dials
"0" , the assigned extensions shall
ring.
0
Conditions
None