Program 20 : System Option Setup
20-21 : System Options for Long Conversation
Level:
IN
Description
Use Program 20-21 : System Options for Long Conversation to define the system options for the
Long Conversation feature.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Long Conversa-
tion Alarm 1
0 ~ 64800 seconds The warning tone for long toll calls
sounds after this time.
170 14-01-15
02 Long Conversa-
tion Alarm 2
0 ~ 64800 seconds After the initial long toll call warning
tone, additional warning tones
sound after this time.
180 14-01-15
03 Long Conversa-
tion Cutoff for In-
coming Call
0 ~ 64800 seconds This timer determines how long the
system waits before disconnecting
an incoming call.
0 14-01-14
04 Long Conversa-
tion Cutoff for
Outgoing Call
0 ~ 64800 seconds This timer determines how long the
system waits before disconnecting
an outgoing call.
0 14-01-14
05 Conversation
cutoff for remote
monitor
0 ~ 64800 seconds 180
Conditions
None
Feature Cross Reference
Long Conversation Cutoff
SL1100
ISSUE 6.0