EasyManua.ls Logo

NEC SL1100 - Program 81: Basic Hardware Setup for Trunk; CO Initial Data Setup

NEC SL1100
650 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 81 : Basic Hardware Setup for Trunk
81-01 : CO Initial Data Setup
Level:
IN
Description
Use Program 81-01 : CO Initial Data Setup to define the various basic data parameters for the
COIU.
Input Data
Item
No.
Item Input Data Default
01 PCM Encoding Method Specifica-
tion
0 = μ-law
1 = A-law
0 (μ-law)
02 Loop Current Detection Time 1 ~ 255
(10 ~ 2550 ms)
60 (600 ms)
03 Clear Signal (Open Loop) Detec-
tion Time
1 ~ 255
(5 ~ 1275 ms)
61 (305 ms)
04 Ringing Signal Detection Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
05 Single Ringing Detection Minimum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
66 (660 ms)
06 Double Ringing Detection Mini-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
10 (100 ms)
07 Double Ringing Detection Maxi-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
40 (400 ms)
08 Ringing Signal not Detection Mini-
mum
1 ~ 255
(10 ~ 2550 ms)
70 (700 ms)
09 Time Ringing Signal Stop Detec-
tion Time
1 ~ 255
(100 ~ 25500 ms)
60 (6000 ms)
10 Continuous Ringing Minimum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
30 (300 ms)
11 Continuous Ringing Maximum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
70 (700 ms)
14 Hook Flash 1 Time 1 ~ 255
(10 ~ 2550 ms)
80 (800 ms)
15 Hook Flash 2 Time 1 ~ 255
(100 ~ 25500 ms)
25 (2500 ms)
16 Pause Time 1 ~ 255
(100 ~ 25500 ms)
10 (1000 ms)
17 PFT Idle Detection Time 1 ~ 255
(100 ~ 25500 ms)
30 (3000 ms)
20 Loop Reverse Detect Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
21 Loop Reverse Detect Maximum
Time
1 ~ 255
(10 ~ 2550 ms)
86 (860 ms)
22 Loop Disconnect Detect Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
40 (400 ms)
ISSUE 6.0 SL1100
Programming Manual 2-467
Program
81

Table of Contents

Other manuals for NEC SL1100

Related product manuals