Program 81 : Basic Hardware Setup for Trunk
81-01 : CO Initial Data Setup
Level:
IN
Description
Use Program 81-01 : CO Initial Data Setup to define the various basic data parameters for the
COIU.
Input Data
Item
No.
Item Input Data Default
01 PCM Encoding Method Specifica-
tion
0 = μ-law
1 = A-law
0 (μ-law)
02 Loop Current Detection Time 1 ~ 255
(10 ~ 2550 ms)
60 (600 ms)
03 Clear Signal (Open Loop) Detec-
tion Time
1 ~ 255
(5 ~ 1275 ms)
61 (305 ms)
04 Ringing Signal Detection Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
05 Single Ringing Detection Minimum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
66 (660 ms)
06 Double Ringing Detection Mini-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
10 (100 ms)
07 Double Ringing Detection Maxi-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
40 (400 ms)
08 Ringing Signal not Detection Mini-
mum
1 ~ 255
(10 ~ 2550 ms)
70 (700 ms)
09 Time Ringing Signal Stop Detec-
tion Time
1 ~ 255
(100 ~ 25500 ms)
60 (6000 ms)
10 Continuous Ringing Minimum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
30 (300 ms)
11 Continuous Ringing Maximum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
70 (700 ms)
14 Hook Flash 1 Time 1 ~ 255
(10 ~ 2550 ms)
80 (800 ms)
15 Hook Flash 2 Time 1 ~ 255
(100 ~ 25500 ms)
25 (2500 ms)
16 Pause Time 1 ~ 255
(100 ~ 25500 ms)
10 (1000 ms)
17 PFT Idle Detection Time 1 ~ 255
(100 ~ 25500 ms)
30 (3000 ms)
20 Loop Reverse Detect Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
21 Loop Reverse Detect Maximum
Time
1 ~ 255
(10 ~ 2550 ms)
86 (860 ms)
22 Loop Disconnect Detect Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
40 (400 ms)
ISSUE 6.0 SL1100