Program 10 : System Configuration Setup
10-20 : LAN Setup for External Equipment
Level:
IN
Description
Use Program 10-20 : LAN Setup for External Equipment to define the TCP port/address/etc. for
communicating to external equipment.
Input Data
Type of External Equipment 1 = CTI Server
2 = ACD MIS (V4.0 Added)
4 = Networking System (V1.5 Added)
5 = SMDR Output
6 = DIM Output
9 = 1st Party CTI
11 = O&M Server
12 = Traffic Report Output
13 = Room Data Output for Hotel Service
14 = IP-DECT Directory Access (V3.0 Added)
Item
No.
Item Input Data Default
01 TCP Port 0 ~ 65535 External Device 1 (CTI
Server) = 8181 (V3.0
Changed)
External Device 2
(ACD-MIS) = 4000
(V4.0 Added)
External Device 4 (Net-
working System) =
30000 (V1.5 Added)
External Device 5
(SMDR Output) = 0
External Device 6 (DIM
Output) = 0
External Device 9 (1st
Party CTI ) = 8282
(V3.0 Changed)
External Device 11
(O&M Server) = 8080
External Device 12
(Traffic Report Output)
= 0
External Device 13
(Room Data Output for
Hotel Service) = 0
External Device 14 (IP-
DECT Directory Ac-
cess) = 0 (V3.0 Added)
03 Keep Alive Time 1 ~ 255 seconds 30
Conditions
None