Item No. Item Input Data Description Default
14 Service Protocol for S-point 0 = Keypad facility
1 = Specified Protocol for Aspire sys-
tem
0
15 Call Busy Mode for S-point 0 = Alerting
1 = Disconnect
0
16 Two B-Channel Transfer for
PRI Service
0 = off
1 = on
0
18 Type of Number 0 = Unknown
1 = International number
2 = National number
3 = Network Specific number
4 = Subscriber number
5 = Abbreviated number
ISDN Protocol definition.
Select the number type
for the ISDN circuit.
2
19 Numbering Plan Identifica-
tion
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering plan
5 = Private numbering plan
ISDN Protocol definition.
Select the Numbering
Plan used for the ISDN
circuit.
1
20 Network Exchange Selec-
tion
0 = Standard (same as NI-2)
1 = reserved
2 = reserved
3 = DMS (A211)
4 = 5ESS
5 = DMS (A233)
6 = 4ESS
7 = NI-2
Select the ISDN protocol
for the ISDN circuit
7
21 Number of Ports 0 = Auto
1 = 4 Ports
2 = 8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
0
For PRI (T1) PKG Setup
Physical Port Number
01 ~ 24
Item
No.
Item Input Data Description Default
01 Logical Port Number 1 ~ 84 The start port number of a
T1 line is displayed, and
24 logic ports are auto-
matically assigned to a
DTI (T1) line.
0
02 T1 Signal Format Selection 0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
0
03 Zero Code Suppression 0 = B8ZS
1 = AMI/ZCS
0
04 Line Length Selection 0 = 0 feet ~ 133 feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
0
05 T1 Clock Source 0 = Internal
1 = External
1
ISSUE 6.0 SL1100