Item
No.
Item Input Data Description Default
11 T312 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast da-
ta link. This timer is only valid for Network
side use only.
6
12 T313 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
4
13 T314 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
4
14 T316 (T317 + 1) ~ 254 sec-
onds
Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is sent.
120
15 T317 1 ~ (T316-1) Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is received.
60
16 T318 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
RES is sent. This timer is valid for user
side use only.
4
17 T319 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND is sent. This timer is valid for
user side use only.
4
18 T320 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second when B-channel access: connec-
tion is received or D-channel access: DL-
ESTABLISH confirmation or indication is
received.
30
19 T321 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second of the timer to be started when
STATUS ENQ is received.
30
20 T322 1 ~ 254 seconds Specifies the timer value in 1/100ths of a
second upon D-channel failure.
4
Conditions
None
Feature Cross Reference
ISDN Compatibility
ISSUE 6.0
SL1100
Programming Manual 2-471