Item
No.
Item Input Data Description Default Related
Program
28 RTP Tx Level
Control
0 = Disable
1 = Tx Level Control
mode (V5.0 Changed)
2 = Tx Automatic Level
Control mode (V5.0
Changed)
3 = HLC
Type 1, Type 7 ~
8 = 3 (V1.5
Changed)
Type 9, 11~15 =
0
Type 18 = 3
(V5.0 Added)
29 RTP Tx Level
Control Level
0 ~ 16 (- 24 ~ 24 dB)
0 = - 24 dB
1 = - 21 dB
2 = - 18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
8
30 RTP Tx Automa-
ticLevelControl
Level (V2.0 Add-
ed)
0 ~ 12 (- 42 dbm ~ - 6
dbm)
0 = - 42 dBm
1 = - 39 dBm
:
7 = - 21 dBm
:
11 = - 9 dBm
12 = - 6 dBm
Do not change the setting unless
asked to change by engineer. (V5.0
Deleted)
Select target gain. (V5.0 Deleted)
Effective when PRG 84-31-28 = 2
(V5.0 Deleted)
7 84-31-28
31 RTP Tx HLC
Threshold
0 ~ 42 (- 42 dBm ~ 0
dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
Type 1, Type 7 ~
8 = 36 (V1.5
Changed)
Type 9, 11~15 =
42
Type 18 = 36
(V5.0 Added)
32 RTP Tx Gain
Compression
mode
0 = Disable
1 = Enable
Type 1, Type 7 ~
8 = 1 (V1.5
Changed)
Type 9, 11~15 =
0
Type 18 = 1
(V5.0 Added)
33 RTP Tx Gain
Compression
Threshold
0 ~ 42 (- 42 dBm ~ 0
dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
Type 1, Type 7 ~
8 = 36 (V1.5
Changed)
Type 9, 11~15 =
42
Type 18 = 36
(V5.0 Added)
34 RTP Rx Level
Control (V2.0
Added)
0 = Disable
1 = RX Level Control
Mode
2 = RX Automatic Level
Control
Flag
Do not change the setting unless
asked to change by engineer. (V5.0
Deleted)
Select receive level control mode.
(V5.0 Deleted)
0
35 RTP Rx Level-
Control Level
(V2.0 Added)
0 ~ 16 (- 24 dB ~ + 24
dB)
0 = - 24 dB
1 = - 21 dB
:
8 = 0 dB
:
15 = 21 dB
16 = 24 dB
Do not change the setting unless
asked to change by engineer. (V5.0
Deleted)
Select receive voice level. (V5.0 De-
leted)
Effective when PRG 84-31-34 = 1
(V5.0 Deleted)
8 84-31-34
ISSUE 6.0 SL1100
Programming Manual 2-527
Program