7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
Virtual chassis
Context
bof
Platforms
7210 SAS-S 1/10GE and 7210 SAS-Sx 1/10GE: standalone-vc mode
Description
This command configures the nodes that will be CPM-IMM nodes in a virtual chassis (VC).
The slot number can be set to any number from 1 to 8 as long as it is not in use by another VC member
node. The slot number identifies a specific node or card in the VC similar to the slot ID of a card in a
chassis-based system, and is used in addressing service objects created during provisioning.
An arbitration process in the boot phase ensures that one of the CPM-capable nodes is the active CPM
and the other is the standby CPM. Internally software will always assign CPM A as the active CPM-IMM
node and CPM B as the standby CPM-IMM node. Ports on the logical IMM which is part of the CPM are
referred to using the same format as IMM-only nodes (slot-id/1/port-id).
The MAC address must match the chassis MAC address of the node.
The no form of the command removes the node from the VC.
Parameters
cpmA
Specifies the active CPM-IMM.
cpmB
Specifies the standby CPM-IMM.
slot-num
Specifies the slot number of the node.
Values 1 to 8
mac-address
Specifies the chassis MAC address of the node.
Values xx:xx:xx:xx:xx:xx or xx-xx-xx-xx-xx-xx
3HE 18197 AAAB TQZZA