Default both
startup-alarm alarm-type
Specifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm
is equal to rising or either, a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is
equal to falling or either, a single falling threshold crossing event is generated.
Default either
Values rising, falling, either
cflash-cap-warn
Syntax
cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold] interval seconds
[rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context
config>system>thresholds
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the
access-uplink operating mode
Description
This command enables capacity monitoring of the compact flash specified in this command. The severity
level is warning. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold warning.
Parameters
cflash-id
Specifies the name of the cflash device to be monitored.
Values cf1:, cf2:, uf1: (7210 SAS-T, 7210 SAS-Sx 1/10GE: standalone and
standalone-VC, 7210 SAS-Sx 10/100GE, and 7210 SAS-Mxp)
cf2:, cf2-A:, cf2-B:, uf1:, uf1-A:, uf1-B: (7210 SAS-R6 and 7210 SAS-
R12)
cf1:, cf2: (7210 SAS-S 1/10GE: standalone and standalone-VC)
rising-threshold threshold