7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
start second sunday april 02:00
end first sunday october 02:00
offset 0
exit
zone GMT
----------------------------------------------
A:ALA-12>config>system>time#
6.14.1.3.5.2 Server-address
The server-address command configures an SNTP server for SNTP unicast client mode.
Use the following CLI syntax to configure an SNTP server for unicast client mode.
config>system>time>sntp#
config>system>time>sntp# server-address ip-address version version-number]
[normal|preferred] [interval seconds]
Example: Command usage
The following example shows the command usage to configure an SNTP server for unicast client mode.
config>system>time>sntp#
config>system>time# server-address 10.10.0.94 version
1preferred interval 100
Example: Configuration output
The following is a sample configuration output of SNTP enabled with the server-address command
configured.
A:ALA-12>config>system>time# info
----------------------------------------------
sntp
server-address 10.10.0.94 version 1 preferred interval 100
no shutdown
exit
dst-zone PT start-date 2006/04/04 12:00 end-date 2006/10/25 12:00
zone GMT
----------------------------------------------
A:ALA-12>config>system>time#
6.14.1.3.6 CRON
The cron command supports the Service Assurance Agent (SAA) functions and the ability to schedule
turning on and off policies to meet ‟Time of Day” requirements. CRON functionality includes the ability
to specify the commands that need to be run, when they will be scheduled, including one-time only
functionality (oneshot), interval and calendar functions, as well as where to store the output of the results.
In addition, CRON can specify the relationship between input, output, and schedule. Scheduled reboots,
peer turn ups, service assurance agent tests and more can all be scheduled with CRON, as well as OAM
events, such as connectivity checks, or troubleshooting runs.
CRON elements include Action, Schedule, Script, Time range, and Time of Day.
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.