7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
6.14.1.3.8.3 Filters
In a TOD suite, filters that have entries with time-ranges may not be selected. Similarly, filter entries with a
time-range may not be created while a TOD suite refers to that filter. QoS policies and filters referred to by
a TOD suite must have scope ‟template” (default).
Use the following syntax to configure TOD-suite egress parameters.
config>system>cron
tod-suite tod-suite-name create
egress
filter ip ip-filter-id [time-range time-range-name] [priority priority]
filter ipv6 ipv6-filter-id [time-range time-range-name] [priority priority]
filter mac mac-filter-id[time-range time-range-name] [priority priority]
Example: Command usage to configure TOD-suite egress parameters
config>system>cron>tod-suite$ egress filter ip 100
config>system>cron>tod-suite$
Example: Configuration output
The following is a sample configuration output of an egress IP filter association with filter ID 100.
sim1>config>filter# ip-filter 100 create
A:sim1>config>filter>ip-filter$ entry 10 create
A:sim1>config>filter>ip-filter>entry$
A:sim1>config>system>cron>tod-suite# egress filter ip 100
A:sim1>config>system>cron>tod-suite# info detail
----------------------------------------------
no description
egress
filter ip 100
exit
----------------------------------------------
A:sim1>config>system>cron>tod-suite#
6.14.1.3.8.4 Ingress
This command is an enhancement for specific ingress policies including filter lists and QoS policies. Use
this command to create time-range based associations of previously created filter lists and QoS policies.
Multiple policies may be included and each must be assigned a different priority; in case time-ranges
overlap, the priority will be used to determine the prevailing policy. Only a single reference to a policy may
be included without a time-range. To configure a daily time-range across midnight, use a combination of
two entries. An entry that starts at hour zero will take over from an entry that ends at hour 24.
Use the following syntax to configure time range based associations.
config>system>cron
tod-suite tod-suite-name create
ingress
filter ip ip-filter-id [time-range time-range-name] [priority priority]
filter ipv6 ipv6-filter-id [time-range time-range-name]
filter mac mac-filter-id[time-range time-range-name] [priority priority]
qos policy-id [time-range time-range-name] [priority priority]
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.