7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
Boot options
Description
This command configures a pause, in seconds, at the start of the boot process that allows the user to
interrupt system initialization at the console.
When the user interrupts system initialization, the user is allowed to manually override the parameters
defined in the BOF.
Only one wait command can be defined in the BOF.
Default
3
Parameters
seconds
Specifies the length of the pause at the start of the boot process, in seconds
Values 1 to 10
4.13.2.1.3 Console port configuration
bof-password
Syntax
bof-password password
no bof-password
Context
bof
Platforms
Supported on all 7210 SAS platforms as described in this document, including those operating in access-
uplink mode
Description
This command configures a BOF password. The user must provide the password to edit the BOF
parameters in the boot loader.
This command also implements a mechanism for password recovery. If the user forgets the password, it
can be reset to factory default. When a password is reset, as a security measure to prevent a malicious
access to the configuration files, the system also resets the flash to factory defaults (that is, it removes
all files from the flash, except the boot image file (cf1:\boot.tim) and TiMOS image file (cf1:\
both.tim)), and reboots the node with the factory default settings. After boot up, the user must set up
the box using the same steps used to boot the box the first time after it was received from the factory.
During bootup after a reboot, the user can use the factory default password "password" to edit the BOF
parameters. After the factory default password is used, Nokia recommends that the user should change
the password.