7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
rising-threshold threshold
Specifies a threshold for the sampled statistic. A single threshold crossing event is
generated when the current sampled value is greater than or equal to this threshold, and
the value at the last sampling interval was less than this threshold. A single threshold
crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value falls below this threshold and reaches less than or equal
the falling-threshold value.
Values –2147483648 to 2147483647
Default 0
falling-threshold threshold
Specifies a threshold for the sampled statistic. A single threshold crossing event is
generated when the current sampled value is less than or equal to this threshold, and
the value at the last sampling interval was greater than this threshold. A single threshold
crossing event will also be generated if the first sample taken is less than or equal to this
threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value raises above this threshold and reaches greater than or
equal the rising-threshold value.
Values –2147483648 to 2147483647
Default 0
interval seconds
Specifies the polling period, in seconds, over which the data is sampled and compared
with the rising and falling thresholds.
Values 1 to 2147483647
rmon-event-type
Specifies the type of notification action to be taken when this event occurs
Values log — An entry is made in the RMON-MIB log table for each event
occurrence. This does not create a TiMOS logger entry. The RMON-
MIB log table entries can be viewed using the show system
thresholds command.
trap — A TiMOS logger event is generated. The TiMOS logger utility
then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session, memory log,
cflash file, syslog, or SNMP trap destinations logs.
both — Both an entry in the RMON-MIB logTable and a TiMOS logger
event are generated.
none — No action is taken.