EasyManua.ls Logo

Nokia 7210 SAS-Mxp - System Resource-Profile Commands for a Virtual Chassis

Nokia 7210 SAS-Mxp
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Description
Commands in this context configure generic RMON alarms and events.
Generic RMON alarms can be created on any SNMP object-ID that is valid for RMON monitoring (for
example, an integer-based datatype).
The configuration of an event controls the generation and notification of threshold crossing events
configured with the alarm command.
alarm
Syntax
alarm rmon-alarm-id variable-oid oid-string interval seconds [sample-type] [startup-alarm alarm-
type] [rising-event rmon-event-id rising-threshold threshold] [falling-event rmon-event-id falling
threshold threshold] [owner owner-string]
no alarm rmon-alarm-id
Context
config>system>thresholds>rmon
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the
access-uplink operating mode
Description
This command configures an entry in the RMON-MIB alarm Table. This command controls the monitoring
and triggering of threshold crossing events. In order for notification or logging of a threshold crossing event
to occur there must be at least one associated rmon>event configured.
The agent periodically takes statistical sample values from the MIB variable specified for monitoring and
compares them to thresholds that have been configured with the alarm command. The alarm command
configures the MIB variable to be monitored, the polling period (interval), sampling type (absolute or
delta value), and rising and falling threshold parameters. If a sample has crossed a threshold value, the
associated event is generated.
The no form of this command removes an rmon-alarm-id from the configuration.
Parameters
rmon-alarm-id
Specifies the alarm being configured. The number of alarms that can be created is limited
to 1200.
Values 1 to 65535
variable-oid oid-string
Specifies the variable to be sampled. Only SNMP variables that resolve to an
ASN.1 primitive type of integer (integer, Integer32, Counter32, Counter64, Gauge,
or TimeTicks) may be sampled. The oid-string may be expressed using either the
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.