falling-threshold threshold
Specifies a threshold for the sampled statistic. A single threshold crossing event is
generated when the current sampled value is less than or equal to this threshold, and
the value at the last sampling interval was greater than this threshold. A single threshold
crossing event will also be generated if the first sample taken is less than or equal to this
threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value raises above this threshold and reaches greater than or
equal the rising-threshold value.
Values –2147483648 to 2147483647
Default 0
interval seconds
Specifies the polling period over which the data is sampled and compared with the rising
and falling thresholds.
Values 1 to 2147483647
rmon-event-type
Specifies the type of notification action to be taken when this event occurs.
Values log — An entry is made in the RMON-MIB log table for each event
occurrence. This does not create a TiMOS logger entry. The RMON-
MIB log table entries can be viewed using the show system
thresholds CLI command.
trap — A TiMOS logger event is generated. The TiMOS logger utility
then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session, memory log,
cflash file, syslog, or SNMP trap destinations logs.
both — Both a entry in the RMON-MIB logTable and a TiMOS logger
event are generated.
none — No action is taken.
Default both
startup-alarm alarm-type
Specifies the alarm that may be sent when this alarm is first created. If the first sample is
greater than or equal to the rising threshold value and startup-alarm is equal to rising or
either, a single rising threshold crossing event is generated. If the first sample is less than
or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Values rising, falling, either
Default either