7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Platforms
7210 SAS-T (access-uplink), 7210 SAS-Sx/S 1/10GE (standalone), and 7210 SAS-Sx 10/100GE
(standalone)
Description
This command creates a system-wide group name that is used to associate of service objects (for
example, ports). The status of the group is derived from the status of its members. The group status can
then be used to influence the status of non-member objects. For example, when a group status is marked
as down, the objects that monitor the group change their status accordingly.
The no form of this command removes the group. All object associations must be removed before running
the no oper-group command.
Default
no oper-group
Parameters
name
Specifies the operational group identifier, up to 32 characters.
create
Keyword to create the configuration context. Once the context is created, it is possible to
navigate into the context without the create keyword.
hold-time
Syntax
hold-time
Context
config>system>oper-group
Platforms
7210 SAS-T (access-uplink), 7210 SAS-Sx/S 1/10GE (standalone), and 7210 SAS-Sx 10/100GE
(standalone)
Description
Commands in this context configure hold time information.
group-down
Syntax
group-down time in seconds
no group-down