7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
input
shutdown
exit
output
shutdown
line-length 110
exit
exit
bits2
input
shutdown
exit
output
shutdown
exit
exit
ptp
shutdown
no ql-override
exit
no revert
----------------------------------------------
*A:SAS>config>system>sync-if-timing#
6.16.2 Entering edit mode
To enter edit mode and edit timing references, enter the begin keyword at the config>system>sync-if-
timing# prompt.
Use the following CLI syntax to enter the edit mode.
config>system>sync-if-timing
begin
Example
The following is a sample error message that is displayed if you try to modify sync-if-timing parameters
without entering the begin keyword.
A:ALA-12>config>system>sync-if-timing>ref1# source-port 2/1/1
MINOR: CLI The sync-if-timing must be in edit mode by calling begin before any
changes can be made.
MINOR: CLI Unable to set source port for ref1 to 2/1/1.
A:ALA-12>config>system>sync-if-timing>ref1#
Note:
Use commit to save or abort to discard the changes made in a session.
6.16.3 Configuring timing references
Example: Configuration of timing reference parameters
config>system# sync-if-timing
config>system>sync-if-timing# begin
config>system>sync-if-timing# ref1
config>system>sync-if-timing>ref1# source-port 1/1/1
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.